Sydney shoring contractor fined $170,000 in SafeWork NSW prosecution after plastic bunting failed to stop a fall into an excavation pit

Shoringco Pty Ltd has been fined $170,000 over two work health and safety offences after a traffic controller it employed fell into an excavation pit at a Lane Cove site. The edge of the pit was marked by plastic mesh bunting on star pickets, erected to the head contractor’s instructions, which the Industrial Court found…

7 min read
NSW Industrial Court
Share this storyLinkedInWhatsAppTeamsFacebookX

A line of orange plastic mesh bunting strung between star pickets was the only barrier along the edge of an earth ramp above an excavation pit up to 10 metres deep at a Lane Cove construction site. On 26 September 2022 a clogged concrete line exploded and blew off its pump. A traffic controller employed by Shoringco Pty Ltd fell into the pit, although exactly how she fell has not been established.

The NSW Industrial Court has fined Shoringco $85,000 for each of two Category 2 offences under the Work Health and Safety Act 2011 (NSW). A Category 2 offence is a failure to comply with a health and safety duty that exposes a person to a risk of death or serious injury, contrary to s.32. The fines total $170,000. Justice Paingakulam delivered the sentence on 16 October 2026 in a SafeWork NSW prosecution.

A fence built to mark the edge, not to hold anyone

The site was being developed into a residential aged care facility and commercial premises. Pathways Property Group was the landowner. Carestruct Pty Ltd was the head contractor and Hansen Yuncken Pty Ltd the builder. Shoringco worked on the project as a subcontractor, carrying out demolition, bulk excavation and shoring.

The fence was erected in mid-July 2022 at Carestruct’s instructions. Its star pickets stood between 2.5 and 3 metres apart. On the other side, the ground fell away over several levels to the floor of the pit.

On the afternoon of the incident, two other contractors, Iconic Structures Sydney and Dynamic Concrete Pumping Services, were pouring concrete for a crane base. That work was outside Shoringco’s contracted scope. The pump operators had been told to park their truck at the high point of the site, beside the ramp’s edge. When the line exploded, concrete sprayed far enough to strike cars on the street outside.

The traffic controller suffered serious injuries and spent months in hospital and rehabilitation. The court found that the harm caused was substantial, an aggravating factor for the s.19(1) offence, on the basis of the injuries set out in the agreed facts. Her victim impact statement described the continuing effects. Justice Paingakulam said it was apparent the incident had “fundamentally impacted every aspect” of her life. Four other people were also exposed to the risk of falling into the pit: two concrete pump operators, a concrete truck driver and Hansen Yuncken’s site manager.

One incident, two charges

Shoringco pleaded guilty to a breach of its s.19(1) duty to its own workers and a breach of its s.19(2) duty to other persons at the site. Each offence carries a maximum fine of $1,860,843.

By its pleas, Shoringco accepted that it could have provided adequate edge protection, “such as appropriate temporary fencing of sufficient strength to withstand the force of a person leaning on, or falling against, it”. It also accepted that it could have enforced an exclusion zone separating plant from pedestrians. An exclusion zone is an area kept clear of people while plant operates. The s.19(1) charge added a failure to instruct workers on keeping a safe distance from vehicles and plant.

The prosecutor acknowledged that two charges were laid only to reflect Shoringco’s different relationships with the people exposed, and that the court was “more or less dealing with one offence divided into two”.

Where the two sides drew the risk

SafeWork NSW submitted

that the danger of falling from height on excavation sites, and the hazards of concrete placing equipment, were widely recognised. It argued that adequate edge protection and an exclusion zone around the pumping would have been simple to put in place and would have cut the risk substantially. It also argued that leaving them out produced a serious risk that could have serious consequences.

Shoringco submitted

that the pleaded risk was falling into the pit, not working near a pressurised concrete line. On that basis, it said, the exclusion zone and instruction measures had limited if any relevance to how serious the offences were. It said the concreting was outside its control, and that fence height had not been pleaded. It noted that the fence was common on construction sites, complied with its safe work method statement (the document setting out how a high-risk task will be done safely), and was installed at the direction of Carestruct’s project manager.

The court found

that the exclusion zone and instruction were lesser, alternative measures made necessary “because of the absence of appropriate fencing”. It held that the primary failing was a fence “which had no capacity to prevent someone who fell against it from falling into the pit”. Building proper fencing was “not burdensome”. The court accepted that enforcing an exclusion zone was complex where Shoringco did not control the pour. It placed both offences in the mid-range of objective seriousness.

Justice Paingakulam accepted that Shoringco’s moral culpability was reduced because it had built the fencing to the principal contractor’s specifications and in line with its own safe work method statement. The court found it was “entitled to be satisfied that it had met the requirements placed on it by relevant third parties”. The judge added:

“As the specialist excavator at the Site, Shoringco should have been aware of the deficient nature of the fencing, particularly in view of the proximity of the edge of the excavation pit to the dirt vehicle parking platform.”

How $200,000 per offence became $85,000

The court set $200,000 as the appropriate fine for each offence. It reduced each by 15% for the guilty pleas, to $170,000. It then took a further $85,000 off each under the totality principle, which requires the combined penalty to reflect the overall criminality where offences overlap.

The pleas came on 19 June 2026, just over four weeks before a 10-day joint hearing listed from 20 July 2026. Proceedings had been commenced on 26 September 2024. The court took into account unchallenged evidence that some delay arose from the prosecutor’s “belated acceptance” that Shoringco was not the principal contractor at the site. Shoringco was convicted of both offences on 18 September 2026.

When the incident occurred, Shoringco had operated for more than eight years with no prior convictions. The court found it was of good character, unlikely to reoffend and had good prospects of rehabilitation. It also found the company had shown remorse. No submission was made that the fines should be reduced for incapacity to pay. In setting the fines, the court took into account that Shoringco is a small family business whose 12 employees and their families depend on it for their income.

Shoringco must also pay SafeWork NSW’s costs, as agreed or assessed. Under s.122(2) of the Fines Act 1996 (NSW), half of each fine goes to the prosecutor.

The company’s account

Shoringco’s sole director at the time was on site most days. He gave evidence that he was deeply remorseful and accepted responsibility on the company’s behalf. The court accepted his apology as genuine. In cross-examination he accepted that the fencing was deficient and that Shoringco should have identified this before the incident. He also agreed that nothing had prevented the company from putting up the post-incident fence sooner. He conceded a failure in Shoringco’s systems to relay and document an instruction not to enter the site during concrete pumping. He maintained that Shoringco’s role in the incident “was very limited”.

After a prohibition notice (a regulator’s direction to stop an activity until a risk is fixed), Shoringco put a concrete jersey barrier and a fence 1.8 metres high along the ramp’s edge. In early 2023 it appointed a WHS manager and introduced site monitoring software. It no longer provides traffic control services. In May 2026 the company changed its name to SC Services NSW Pty Ltd and restructured to provide plant and labour hire rather than contract works. Personnel are now placed only after a safety assessment of the worksite. The former director resigned on 29 May 2026 but remains engaged at a management level. The company now has a different director.

  • 26 Sep 2022 Concrete line explodes and a traffic controller falls into the excavation pit.
  • 26 Sep 2024 SafeWork NSW commences proceedings.
  • 19 Jun 2026 Shoringco pleads guilty to both charges.
  • 18 Sep 2026 Sentence hearing and convictions recorded.
  • 16 Oct 2026 Fines of $85,000 per offence imposed.

At a glance

  • Parties: SafeWork NSW v Shoringco Pty Ltd (now SC Services NSW Pty Ltd)
  • Citation: [2026] NSWIC 60, Paingakulam J
  • Sections: Work Health and Safety Act 2011 (NSW), s.19(1), s.19(2) and s.32
  • Outcome: $85,000 per offence, $170,000 total, plus the prosecutor’s costs
  • Who it affects: Shoringco, its injured traffic controller and four other people exposed to the risk

Shoringco installed edge protection to the head contractor’s design and in line with its own safe work method statement. As the specialist excavator on site, it was still responsible for making that protection adequate. Following the design reduced its moral culpability but did not remove its liability.

Source: [2026] NSWIC 60

General information only. OnNotice reports developments in Australian industrial relations, human resources and workplace law. This article is for education purposes only and is not intended to form professional advice. Always confirm against the primary source and seek specific advice relating to your circumstances.

Share this storyLinkedInWhatsAppTeamsFacebookX

Keep reading