A second-year apprentice and a co-worker who was not permitted to do any electrical work were running cables and pulling switches out of the walls of a Noble Park property on 22 April 2024 while the installation was still live. No A-grade electrician was there to supervise them or to carry out the isolation.
Their employer, Fuzed Electrical Solutions Pty Ltd, pleaded guilty in the Dandenong Magistrates’ Court to a WorkSafe Victoria charge of failing to provide a safe system of work under the Occupational Health and Safety Act 2004. The company was convicted, fined $20,000 and ordered to pay $4,452 in costs.
At a glance
- Parties: WorkSafe Victoria v Fuzed Electrical Solutions Pty Ltd
- Court: Dandenong Magistrates’ Court
- Legislation: Occupational Health and Safety Act 2004; Occupational Health and Safety Regulations 2017
- Charge: Failure to provide a safe system of work
- Incident date: 22 April 2024
- Outcome: Guilty plea; convicted, fined $20,000, costs of $4,452
- Without the plea: $35,000 fine with conviction (s.6AAA, Sentencing Act 1991)
The company’s business is electrical work associated with fitting roller shutters and awnings, and it had been hired to pre-wire a single-storey property in Noble Park. The job was ‘electrical rough in’ work. That meant feeding cables through the roof space and down inside the walls to where switches were to go, and taking light switches and power points off the walls.
The residual current device (the safety switch) on the switchboard had not been isolated, which made the job live electrical work. Under guidance material, a second-year apprentice needed direct or general supervision, depending on the task, and an A-grade electrician had to be on site the whole time. The other employee was not a registered apprentice and did not hold a construction card (the induction card required to work on construction sites). That worker was barred from doing electrical work of any kind, whether supervised or not. Contact with exposed energised terminals exposed both workers to the risk of electric shock or electrocution, with the potential for serious injury or death.
A WorkSafe inspector attended and issued improvement notices (written directions requiring an employer to fix a contravention). One was for failing to prepare a safe work method statement, or SWMS (a document setting out the hazards and controls for high-risk construction work), for work on or near energised electrical installations. The other was for failing to supervise employees.
A safe system of work would have had the installation isolated before the job started. One way of doing this was a standard operating procedure under which, before work began, a lock-dog, screwdriver, padlock or similar device was applied. The isolation point would be tagged out, and the installation tested for voltage to confirm the isolation had worked. The isolation itself would be done by an A-grade electrician, or by an apprentice under the direct supervision of one.
In sentencing, the court took into account the guilty plea and character references. It found the reference from the company’s accountant “particularly persuasive as it indicated how diligently the business was usually run”. It placed a strong emphasis on general deterrence and said: “Because the risk did not eventuate does not mean a lower penalty.”
The court said an inspector had passed by and seen unsafe conditions, and that “the offender’s conduct represents a culture of people not worrying about SWMS and leaving apprentices unsupervised until they are caught by WorkSafe.”
The court pointed to an earlier interaction between the company and WorkSafe in 2022, saying the company should have known the regulator would become involved. It observed that there is “a high degree of non-conviction when offenders are first time before the Court”, but said general deterrence weighs heavily in sentencing. The court had received nothing to show why a conviction would be especially crushing for the business, and said “there needs to be a clear message”.
Under s.6AAA of the Sentencing Act 1991, which requires a court to state the sentence it would have imposed without a guilty plea, the court said that but for the plea it would have fined the company $35,000 with conviction.
Source: WorkSafe Victoria, 1 October 2026
General information only. OnNotice reports developments in Australian industrial relations, human resources and workplace law. This article is for education purposes only and is not intended to form professional advice. Always confirm against the primary source and seek specific advice relating to your circumstances.